H3C G3服务器硬盘报错后立即自动rebuilding处理

丹柯yx 2023-10-26 阅读 24

H3C G3服务器硬盘报错后立即自动rebuilding处理_硬盘

2023-10-07 22:16:40 RAID_Array 触发 严重 Transition to Critical from less severe---PCIe slot:2

2023-10-07 22:19:36 HDD_F02_Status Drive Slot (Bay) 触发 正常 Rebuild/Remap in progress

2023-10-09 01:20:59 HDD_F02_Status Drive Slot (Bay) 解除 正常 Rebuild/Remap in progress

2023-10-09 01:21:07 RAID_Array add_in_card 触发 正常 Transition to OK---PCIe slot:2

10.7号22:16分报slot 2硬盘故障,紧接着22:19分该位置硬盘开始自动同步。等自动同步完成正常运行几天后又报slot2位置硬盘预故障,需要更换。以后遇到硬盘报错后立即自动rebuilding可取消rebuild直接进行硬盘更换操作,硬盘存在介质性报错。

H3C G3服务器硬盘报错后立即自动rebuilding处理_硬盘_02

2023-10-14 07:23:45 HDD_F02_Status Drive Slot (Bay) 触发 轻微 Predictive failure


第二台同样问题:

H3C G3服务器硬盘报错后立即自动rebuilding处理_硬盘_03

H3C G3服务器硬盘报错后立即自动rebuilding处理_raid_04

2023-10-22 10:01:39 RAID_Array Add-in Card 触发 严重 Transition to Critical from less severe---PCIe slot:2---LDDevno :1

2023-10-22 10:04:10 HDD_F09_Status Drive Slot (Bay) 触发 正常 Rebuild/Remap in progress

使用阵列卡工具storcli64查看磁盘介质性错误

#storcli64 /c0/eall/sall show all |grep -e "Error Count" |grep -A 3 -B 3

查看到1号硬盘 Media Error Count 691;

9、11号硬盘Other Error Count 7,根据经验分析Other Error Count与磁盘健康关系更大。9号硬盘 从raid卡日志看到有Command timeout。

#storcli /c0 show events > /tmp/raid-events.log //导出raid卡events日志查看

H3C G3服务器硬盘报错后立即自动rebuilding处理_raid_05

H3C G3服务器硬盘报错后立即自动rebuilding处理_硬盘_06

H3C G3服务器硬盘报错后立即自动rebuilding处理_raid_07

H3C G3服务器硬盘报错后立即自动rebuilding处理_硬盘_08

H3C G3服务器硬盘报错后立即自动rebuilding处理_raid_09

H3C G3服务器硬盘报错后立即自动rebuilding处理_raid_10

同步一天多时间没完成,报出9号硬盘故障