在创建程序之前,从元素数据区选择合适的面作为安全平面,拖放到机器状态区“间距面”窗口,并设置好合适的参数,点击“应用”使安全平面生效。
$$/* Header
DMISMN/'Created by [爱科腾瑞科技(北京)有限公司-091521-DEMO-11022(华清)] on 星期五, 五月 21, 2021', 4.0
UNITS/MM, ANGDEC, MMPS
WKPLAN/XYPLAN
PRCOMP/ON
TECOMP/ON
FLY/1.0000
MODE/MAN
SNSET/APPRCH, 2.0000
SNSET/RETRCT, 2.0000
SNSET/DEPTH, 0.0000
SNSET/SEARCH, 10.0000
SNSET/CLRSRF, 20.0000
RECALL/D(MCS)
SNSLCT/S(D2L20)
GEOALG/BF, LSTSQR
GEOALG/ANGLB, DEFALT
GEOALG/CIRCLE, LSTSQR
GEOALG/ARC, LSTSQR
GEOALG/PLANE, LSTSQR
$$
$$
$$*/
MODE/MAN
F(PLN1)=FEAT/PLANE,CART,31.6201,36.7677,0.0000,0.0000,0.0000,1.0000
$$ Measurement points are created through nominal points
MEAS/PLANE, F(PLN1), 4
PTMEAS/CART, 3.1807, 62.9535, 0.0000, 0.0000, 0.0000, 1.0000
PTMEAS/CART, 5.5886, 6.1720, 0.0000, 0.0000, 0.0000, 1.0000
PTMEAS/CART, 58.0215, 6.1515, 0.0000, 0.0000, 0.0000, 1.0000
PTMEAS/CART, 59.6897, 71.7937, 0.0000, 0.0000, 0.0000, 1.0000
ENDMES
D(CRD1) = DATSET/FA(PLN1), ZDIR
F(LN1)=FEAT/LINE,BND,CART,4.0093,0.0000,-2.8089,61.0046,0.0000,-2.6485,0.0000,-1.0000,0.0000
$$ Measurement points are created through nominal points
MEAS/LINE, F(LN1), 2
PTMEAS/CART, 4.0093, 0.0000, -2.8089, -0.0000, -1.0000, -0.0000
PTMEAS/CART, 61.0046, 0.0000, -2.6485, -0.0000, -1.0000, -0.0000
ENDMES
F(LN2)=FEAT/LINE,BND,CART,0.0000,5.6751,-1.6435,0.0000,57.5141,-2.3502,-1.0000,0.0000,0.0000
$$ Measurement points are created through nominal points
MEAS/LINE, F(LN2), 2
PTMEAS/CART, 0.0000, 5.6751, -1.6435, -1.0000, 0.0000, 0.0000
PTMEAS/CART, 0.0000, 57.5141, -2.3502, -1.0000, 0.0000, 0.0000
ENDMES
F(PT_INTER1)=FEAT/POINT,CART,0.0018,0.0085,-2.1933,-0.0028,0.0136,0.9999
CONST/POINT,F(PT_INTER1),INTOF,FA(LN1),FA(LN2)
D(CRD2) = DATSET/FA(PLN1), ZDIR, ZORIG, FA(LN1), XDIR, FA(PT_INTER1), XORIG
D(CRD2) = TRANS/ZORIG, -0, YORIG, FA(PT_INTER1), XORIG, -0
MODE/PROG,MAN
$$ MACRO: EASI_CLEARPLN_GOTO
$$ FUNCTION: CLEARANCE SURFACE IMPLEMENTATION
$$ Move machine CLEAR SURFACE DIST above the current clear surface
$$ plane and then move machine parallel to the clear surface plane
$$ ALL Macro parameters are in PCS and Current UNITS
$$ Last update: 3-1-04 Add mode checking. only works in PROG MODE
$$ Last update: 8-24-04 Clear position is based on the surface of
$$
$$ This sample DMIS Macro is provided by External-Array Software, Inc.
$$ It should be modified for your own use. There is no guarantee for
$$ the quality of this Macro. November, 2003
M(EASI_CLEARPLN_GOTO) = MACRO/ISNOM, TARX, TARY, TARZ
DECL/LOCAL, REAL, CCX, CCY, CCZ, CCI, CCJ, CCK
DECL/LOCAL, REAL, CURX, CURY, CURZ, TD, CLRDIST, SDIAM
DECL/LOCAL, CHAR, 255, CLRLABEL, FLABEL, MMODE, SNAME
MMODE = VALUE/MODE
CLRLABEL = VALUE/SNSET, CLRSRF
IF/ ( (LEN(CLRLABEL) .GT. 0) .AND. (MMODE .EQ. 'PROG,MAN') )
CLRDIST = VALUE/SNSET, CLRSRF, DIST
FLABEL = ASSIGN/'FA'
IF/ ISNOM .EQ. 0
FLABEL = ASSIGN/'F'
ENDIF
CCX = OBTAIN/FLABEL(@CLRLABEL), 3
CCY = OBTAIN/FLABEL(@CLRLABEL), 4
CCZ = OBTAIN/FLABEL(@CLRLABEL), 5
CCI = OBTAIN/FLABEL(@CLRLABEL), 6
CCJ = OBTAIN/FLABEL(@CLRLABEL), 7
CCK = OBTAIN/FLABEL(@CLRLABEL), 8
SNAME = VALUE/SNSLCT
SDIAM = OBTAIN/SS(SNAME), 8
CCX = ASSIGN/CCX + CCI * SDIAM/2
CCY = ASSIGN/CCY + CCJ * SDIAM/2
CCZ = ASSIGN/CCZ + CCK * SDIAM/2
CURX = VALUE/GOTOM, XAXIS
CURY = VALUE/GOTOM, YAXIS
CURZ = VALUE/GOTOM, ZAXIS
TD = ASSIGN/(CURX - CCX) * CCI + (CURY - CCY) * CCJ + (CURZ - CCZ) * CCK
IF/ TD .LT. CLRDIST
TD = ASSIGN/(CLRDIST - TD)
GOTO/CURX+CCI*TD, CURY+CCJ*TD, CURZ+CCK*TD
ENDIF
TD = ASSIGN/(TARX - CCX) * CCI + (TARY - CCY) * CCJ + (TARZ - CCZ) * CCK
IF/ TD .LT. CLRDIST
TD = ASSIGN/(CLRDIST - TD)
GOTO/TARX+CCI*TD, TARY+CCJ*TD, TARZ+CCK*TD
ENDIF
ENDIF
ENDMAC
SNSET/APPRCH, 2.0000
SNSET/RETRCT, 2.0000
SNSET/DEPTH, 0.0000
SNSET/SEARCH, 10.0000
SNSET/CLRSRF, FA(PLN1), 20.0000